CISA ICS Advisory: Digital Watchdog VMAX DVR and NVR Product Lineups
Here’s what this advisory affects, and what to do about it.
This organization is reported to have suffered a critical-severity data breach. Full verified details will be added here as they are confirmed.
On September 15, 2026, the Cybersecurity and Infrastructure Security Agency (CISA) released an ICS advisory detailing multiple vulnerabilities in the Digital Watchdog VMAX DVR and NVR product lineups.
Watch this company
Get alerted the next time this company files a breach with any US regulator — the filing, dated and sourced. A free single-company slice of Signals; no account needed.
We’ll email you only about this company’s future breach filings and how to watch a whole vendor list — not general marketing. Unsubscribe any time.
Watching your whole vendor list (50 to 500 companies, by tier) is GalaxyWarden Signals.
Remote code execution via multiple flaws
The advisory indicates that successful exploitation of these vulnerabilities could grant full administrative control of the device. This would allow an attacker to view live and recorded surveillance, alter device configurations, and use the device as a network pivot point. The advisory does not state whether the vulnerabilities have been exploited in the wild.
- Every indexed leak tied to your address — all of them, named and dated
- What this kind of incident typically exposes
- A ten-minute lock list written for this kind of organisation
Affected products
The following versions are affected:
- VMAX A1 G4 DVRs — all versions (vers:all/*)
CISA has assigned six CVEs to the issues: CVE-2026-68953, CVE-2026-66890, CVE-2026-68070, CVE-2026-68950, CVE-2026-66887, and CVE-2026-66372.
What to do
- Determine whether any VMAX A1 G4 DVRs are present in your environment.
- Consult Digital Watchdog for available firmware updates addressing these vulnerabilities.
- Apply vendor-provided patches as soon as they become available.
- Implement network segmentation to limit exposure of affected devices to untrusted networks.
- Monitor the vendor’s security channel and CISA’s ICS advisories for further updates.
Organizations operating these surveillance devices should prioritize assessment and remediation to prevent potential compromise that could affect both device integrity and broader network security.
What the free scan actually returns
Found on people-search siteswe remove these
These listings are live, public, and legal to remove — and removing them is what we do.
Found in breach recordsverifiedreported — unverified
Each record is labeled: confirmed breach data, or an attacker’s claim no one has verified.
Leaked data cannot be deleted from the internet — anyone claiming otherwise is lying. Broker listings can be removed. We do the second, and show you exactly what to fix from the first.
Report details & sourcing
Related breaches
CISA ICS Advisory: Wärtsilä FOS-Onboard
Successful exploitation of these vulnerabilities could allow an attacker to deliver an unauthorized …
CISA ICS Advisory: mySCADA myPRO Manager
Successful exploitation of these vulnerabilities could allow an attacker to access privileged manage…
AVL Growth Partners, an Ampleo Data Breach Notice (Vermont Attorney General)
AVL Growth Partners, an Ampleo notified Vermont residents of a data breach in a filing reported to t…