CISA ICS Advisory: Siemens Solid Edge
Here’s what this advisory affects, and what to do about it.
Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions. The following versions of Siemens Solid Edge are affected: Solid Edge SE2025 vers:intdot/ Solid Edge SE2026 vers:intdot/
CISA published an Industrial Control Systems advisory on August 13, 2026, warning that Siemens Solid Edge contains multiple file parsing vulnerabilities.
File parsing flaws in PAR, PSM and DFT files
The advisory states that Solid Edge is affected by multiple vulnerabilities that can be triggered when the application reads specially crafted files in PAR, PSM, or DFT format. Successful exploitation could allow an attacker to crash the application or execute arbitrary code. The advisory does not say whether the flaws have been exploited in the wild.
Watch this company
Get alerted the next time this company files a breach with any US regulator — the filing, dated and sourced. A free single-company slice of Signals; no account needed.
We’ll email you only about this company’s future breach filings and how to watch a whole vendor list — not general marketing. Unsubscribe any time.
- Every indexed leak tied to your address — all of them, named and dated
- A deeper search of collected breach data — the kinds of your information it holds, where it finds you
- What this kind of incident typically exposes
- A ten-minute lock list written for this kind of organisation
Affected products
The following versions are affected:
- Solid Edge SE2025 vers:intdot/
- Solid Edge SE2026 vers:intdot/
Siemens has released updated versions of the affected products.
What to do
- Update all installations of Solid Edge SE2025 and Solid Edge SE2026 to the latest versions released by Siemens.
- Verify that the deployed versions match the updated releases provided by the vendor.
- Until updated, restrict opening of untrusted PAR, PSM, or DFT files in Solid Edge.
- Monitor Siemens’ official product security channel for any additional guidance.
- Apply the vendor’s recommended mitigations where immediate patching is not possible.
Organisations that procure or maintain engineering workstations running Solid Edge should treat this advisory as priority maintenance.
What the free scan actually returns
Found on people-search siteswe remove these
These listings are live, public, and legal to remove — and removing them is what we do.
Found in breach recordsverifiedreported — unverified
Each record is labeled: confirmed breach data, or an attacker’s claim no one has verified.
Leaked data cannot be deleted from the internet — anyone claiming otherwise is lying. Broker listings can be removed. We do the second, and show you exactly what to fix from the first.
Report details & sourcing
Related breaches
CISA ICS Advisory: Siemens Industrial Software Products
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerabili…
CISA ICS Advisory: Siemens RUGGEDCOM APE1808
Fortinet has published information on a Double Free vulnerability in FortiOS. This advisory lists th…
CISA ICS Advisory: Siemens Industrial Automation Software Products
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerabili…