CISA ICS Advisory: Mitsubishi Electric Multiple FA Products (Update D)
Here’s what this advisory affects, and what to do about it.
Successful exploitation of this vulnerability could allow a remote attacker to cause a denial-of-service (DoS) condition, a timeout error, or a communication delay by sending a specially crafted UDP packet to the product. The following versions of Mitsubishi Electric Multiple FA Products (Update D) are affected: Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32D Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32T Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32TE Mitsubishi Electric CC-Link IE TSN Remote I/O module NZ2GN2S1-32DT Mitsubishi Electric
On August 27, 2026, the Cybersecurity and Infrastructure Security Agency (CISA) published an updated Industrial Control Systems (ICS) advisory detailing a vulnerability in specific Mitsubishi Electric factory automation products.
Watch this company
Get alerted the next time this company files a breach with any US regulator — the filing, dated and sourced. A free single-company slice of Signals; no account needed.
We’ll email you only about this company’s future breach filings and how to watch a whole vendor list — not general marketing. Unsubscribe any time.
Remote DoS via crafted UDP packet
The advisory states that successful exploitation of the vulnerability could allow a remote attacker to cause a denial-of-service condition, a timeout error, or a communication delay by sending a specially crafted UDP packet to the affected product. The advisory does not say whether the flaw has been exploited in the wild.
- Every indexed leak tied to your address — all of them, named and dated
- A deeper search of collected breach data — the kinds of your information it holds, where it finds you
- What this kind of incident typically exposes
- A ten-minute lock list written for this kind of organisation
Affected products
The following CC-Link IE TSN Remote I/O modules are affected:
- NZ2GN2S1-32D
- NZ2GN2S1-32T
- NZ2GN2S1-32TE
- NZ2GN2S1-32DT
No other versions or products are named in the advisory.
What to do
- Check operational environments for the four listed NZ2GN2S1- module part numbers.
- Apply the updated firmware or mitigations provided by Mitsubishi Electric for these specific modules.
- Restrict network access to the affected modules so that untrusted UDP traffic cannot reach them.
- Monitor Mitsubishi Electric’s official support channels for any further updates to this advisory.
- Review network segmentation controls for ICS environments that use CC-Link IE TSN.
Organizations operating industrial control systems should treat this class of remote denial-of-service vulnerability as a priority for networks where availability is critical.
What the free scan actually returns
Found on people-search siteswe remove these
These listings are live, public, and legal to remove — and removing them is what we do.
Found in breach recordsverifiedreported — unverified
Each record is labeled: confirmed breach data, or an attacker’s claim no one has verified.
Leaked data cannot be deleted from the internet — anyone claiming otherwise is lying. Broker listings can be removed. We do the second, and show you exactly what to fix from the first.
Report details & sourcing
Related breaches
CISA ICS Advisory: Siemens Industrial Automation Software Products
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerabili…
CISA ICS Advisory: Siemens Industrial Software Products
On October 21, 2026, the Node.js project released security updates addressing a critical vulnerabili…
CISA ICS Advisory: Siemens Building Automation and Energy Products
On October 21, 2026, the PHP project and security researchers disclosed two critical, unauthenticate…